THERM 18 KD

THERM 18 KD

The THERM 18 condensing boiler series combines top technology, based in the latest findings in the field, and state-of-the-art components allowing active control of the combustion operation with regard to gas consumption, preventing unnecessary energy loss. The boilers have stainless exchanger with cooled front burner wall. The new type of the gas valve in combination with the burner provides a high level modulation. The regulation ratio of this type of boiler is then 1:10 and the minimum output starts at 1.8 kW. The boiler represents the PREMIUM Condens series with superior technological design.

Thanks to the broad range of output modulation, from 1.8 kW to 19.0 kW, the boilers are designed to be used in low-energy buildings with low heat loss. The THERM 18 KD version is designed for heating. With an added external tree-way valve and indirect heating reservoir, it is possible to heat household water and thus utilise the maximum capability of the boiler unit.

 

Recommended retail price: on request

eu_flagThe product THERM 18 KD complies all legislative, safety, healthy and environmental requirements of the European Union and CE mark enables the free movement of products within the market of the European Economic Area.

Information Sheet

Do you have a question?
Do you need installation?
Emission category NOx 6View the ErP label
  • There is also the option to heat water in an external reservoir and fitting with a three-way valve
  • The product is designed for heating systems
  • Exceptionally ecological operation – Class NOx 6
  • Condensing body with a brand new type of boiler: BLUEJET®
  • Broad modulation range: from 1.8 kW to 19.0 kW
  • New design of a multiphase fan
  • Noise reduction at higher speed
  • Electrically modulated SGV gas valve
  • Modulated high-efficiency circulating pump
  • New control unit with auto-diagnostics
  • The electronic system receives feedback about the status of burning and performs optimisation of the program map
  • Suitable combination with the floor heating system
  • Boiler communication and regulator via OpenTherm+
Class of seasonal energy efficiency of heating

A

Nominal thermal input power

18.0

Min. – max. thermal output for heating

1.8 – 19.0

Fuel

natural gas / propane

Gas consumption - natural gas

0.181 – 1.749

Gas consumption - propane

0.070 – 0.711

Min. – max. overpressure of heating system

0.8 – 3.0

Maximum input pressure of heating water

80

Boiler efficiency

99 – 106

Volume of expansion unit

7

Nominal supply voltage / frequency

230/50~

Auxiliary electricity at rated heat input

68.2

Level of coverage of electrical part

IP 41 (D)

Diameter of smoke flue

60/100, 80/125, 2×80

Dimensions: height / width / depth

725 / 430 / 280

Weight of boiler

28

Order number

10105