THERM 20 LXZE.A 5

THERM 20 LXZE.A 5

The THERM 20 LXZE.A 5 wall-hung gas boiler with built-in storage tank is suitable for heating and preparing domestic hot water in small and medium-sized flats with insufficient space for the combination of the boiler and the stand-alone tank. The boiler is suitable for placement in the interior. There is no need for further connections between the boiler and the tank, all form a single unit. Fluently regulation of the boiler output from 8.0 kW and the low emission burner guarantee both ecological and economical operation.

We have reduced energy consumption costs together with minimum emissions into the air. The boiler is available in two versions according to the type of fuel, i.e. natural gas or propane combustion. The boiler output can be adapted to the immediate heating loses in the area over 40-100% of the boiler output.

 

Recommended retail price: on request

eu_flagThe product THERM 20 LXZE.A 5 complies all legislative, safety, healthy and environmental requirements of the European Union and CE mark enables the free movement of products within the market of the European Economic Area.

Information Sheet

Do you have a question?
Do you need installation?
Emission category NOx 6View the ErP labelView the ErP label
  • Wall boilers with a built-in reservoir
  • The boiler includes a 55 l (stainless) indirect heating reservoir
  • The boiler has a three-way valve for alternatively heating the heating system and the hot water storage tank
  • Water cooled low-emission burner
  • Simple and intuitive control
  • Fluent boiler output regulation
  • Can be regulated according to the spatial or outdoor temperature (equitherm regulation)
  • Great efficiency and low gas consumption
  • Can be combined with a floor heating system
  • Can be controlled by a room thermostat or intelligent room regulator through OpenTherm+
Energy efficiency class of water heating

B

Declared loading profile

L

Nominal thermal input power

22,2

Min. – max. thermal output for heating

8,0 – 20,0

Fuel

natural gas / propane

Gas consumption - natural gas

0,90 – 2,30

Gas consumption - propane

0,34 – 0,85

Min. – max. overpressure of heating system

0,8 – 3,0

Maximum input pressure of heating water

80

Boiler efficiency

92

Volume of expansion unit

10

Volume of the integrated tank

55 (stainless)

Volume of expansion unit of DHW

2

Nominal supply voltage / frequency

230/50~

Auxiliary electricity at rated heat input

65

Level of coverage of electrical part

IP 44

Diameter of smoke flue

120

Dimensions: height / width / depth

830 / 800 / 390

Weight of boiler

62