THERM 24 KDCN

THERM 24 KDCN

The THERM 24 KDCN boiler is for a heating system and flow heating utility water. The water is heated by a secondary plate exchanger that is part of the boiler. The advantages of this method of heating utility water are the compact dimensions for small spaces and the low price of device.

The boiler has heating power of 4.9 to 20.7 kW for the heating. Heating power of up to 24.0 kW is reserved for heating utility water. The boiler can provide the maximum convenience in supplying hot water.

 

Recommended retail price: on request

eu_flagThe product THERM 24 KDCN complies all legislative, safety, healthy and environmental requirements of the European Union and CE mark enables the free movement of products within the market of the European Economic Area.

Information Sheet

Do you have a question?
Do you need installation?
Emission category NOx 6View the ErP labelView the ErP label
  • Flow hot water heating in the secondary plate exchanger
  • Energy saving pump
  • Micro processor automatic control system
  • Stainless condensing body
  • Fluent output regulation
  • Can be regulated according to the spatial or outdoor temperature (equitherm regulation)
  • Great efficiency using the water steam condensing principle from burnt gases
  • Boiler communication through OpenTherm+ protocol
  • LCD parameters display
  • Can be combined with a floor heating system
  • Reliability and long service life
Class of seasonal energy efficiency of heating

A

Energy efficiency class of water heating

A

Declared loading profile

L

Nominal thermal input power

20.6

Min. – max. thermal output for heating

4.9 – 20.7

Max. thermal output for DHW

24.0

Fuel

natural gas / propane

Gas consumption - natural gas

0.48 – 2.04

Gas consumption - propane

0.20 – 0.80

Min. – max. overpressure of heating system

0.8 – 3.0

Maximum input pressure of heating water

80

Boiler efficiency

99 – 107

Volume of expansion unit

7

Nominal supply voltage / frequency

230/50~

Auxiliary electricity at rated heat input

74.5

Level of coverage of electrical part

IP 41 (D)

Diameter of smoke flue

60/100, 80/125, 2×80

Dimensions: height / width / depth

725 / 430 / 285

Weight of boiler

34

Order number

1091